Perform electrical NDT test to send electrical pulses throughout the frame to detect harmonic resonances in order to verify the extent of the damaged area.

         Damage portion is carefully sanded away, plus an extended area about 1-1/2” around the crack or damaged portion.

          Examine the sanded area and view the original fiber orientation.

         After area is built up, it is sanded down a final time to match the same contour of the original frame area.

         The frame is re-painted and the laminate is re-built by matching the orientation of the original fibers with the new layers being applied.